Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
Table 2.45
Indicate current RAPS VLAN ID.
Choose to enable ERPS with this particular VLAN.
Choose the West Port of the RPL.
Choose the East Port of the RPL.
Choose to enable Owner Function.
Set the wait-to-restore (WTR) time of the ring in
minutes. Lower value has lower protection time.
Range from 0 to 12 minutes.
Set the holdoff time of the ring.
Range from 0 to 10000 milliseconds.
Set the guard time of the ring.
Range from 0 to 2000 milliseconds.
Set the maintenance entity group level (MEL) of the
ring.
Range from 0 to 7.
Indicate the topology change propagation of the ring
ability.
Fig. 2.59
Using the same example as above, configurations of two switches can be set up individually
as follows:
Table 2.46